Adding reaction parameters to structural members Issue
When you imported your file from a third-part analysis program into Revit® Structure, you noticed that your structural members have end-reaction parameters. In your default template files, these parameters do not exist. You want to know how to add the parameters without having to import them from the analysis program. Solution
To add reaction parameters to the default template file Click Settings menu > Project Parameters > Add. Select Shared Parameter and then click Select. Browse to the following file:
C:\Documents and Settings\All Users\Application Data\Autodesk\RST 2009\Imperial Library\Annotations\Structural\Structural Framing Tag-w-Reaction Parameters.txt.
Select one of the parameters in the file and click OK. In the Parameter Properties, select the Categories to which you want to add the parameter. In the Parameter Data panel, select a Parameter Group and set it to Instance. Click OK. Repeat this process for each parameter that you want to add.
Give us your feedback on this document:
AUTODESK DOES NOT GUARANTEE THAT YOU WILL BE ABLE TO SUCCESSFULLY DOWNLOAD OR IMPLEMENT ANY SERVICE PACK OR WORKAROUND, OR ANY OF THE TIPS, TRICKS, EXAMPLES OR SUGGESTIONS OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENTS. TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS ARE SUBJECT TO CHANGE WITHOUT NOTICE TO YOU. AUTODESK PROVIDES TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AUTODESK OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF DATA, OR LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, THAT MAY OCCUR AS A RESULT OF IMPLEMENTING ANY SERVICE PACK OR WORKAROUND, OR ANY SUGGESTION OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENT, EVEN IF AUTODESK OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. |