TEC Devices—Troubleshooting TEC Simulations for Unrealistically High Temperatures
Issue
An analysis containing a thermoelectric cooling (TEC) device material seems to have temperatures that are unrealistically high. The resultant temperatures fluctuate wildly, and the TEC has exceeded its maximum current.
Solution
There are two things to look for:
1. Check the setup of the TEC device parameters within the Materials task. Verify that the limiting parameters and Cold-Temperature Surface are correctly defined.
2. Ensure that the device is properly sunk to the surrounding case. If a TEC device is suspended in space with no conduction path to the ambient, temperatures can climb wildly and result in poor results.
AUTODESK DOES NOT GUARANTEE THAT YOU WILL BE ABLE TO SUCCESSFULLY DOWNLOAD OR IMPLEMENT ANY SERVICE PACK OR WORKAROUND, OR ANY OF THE TIPS, TRICKS, EXAMPLES OR SUGGESTIONS OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENTS. TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS ARE SUBJECT TO CHANGE WITHOUT NOTICE TO YOU. AUTODESK PROVIDES TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AUTODESK OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF DATA, OR LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, THAT MAY OCCUR AS A RESULT OF IMPLEMENTING ANY SERVICE PACK OR WORKAROUND, OR ANY SUGGESTION OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENT, EVEN IF AUTODESK OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.