Heat Transfer: Time step size sensitivity of transient heat transfer results with extruded elements
Issue
Transient thermal simulations with extruded mesh can show dramatically different thermal results when the time-step size is small.
In one particular case, a steady state analysis and a transient analysis with a time step size of 50 seconds both show a maximum temperature of 580 C. Reducing the time step to 1 second and re-running the same analysis produced lower maximum temperatures (220 C).
Solution
When an analysis with extruded mesh varies with time, diagonal terms dominate the thermal equations if the time step is sufficiently small. The equations that link the extruded mesh to non-extruded portions are not strong enough to capture the thermal connection adequately. The result is inadequate heat flow.
Increase the time step size.
Mesh such volumes using a standard tetrahedral mesh instead of an extruded mesh.
AUTODESK DOES NOT GUARANTEE THAT YOU WILL BE ABLE TO SUCCESSFULLY DOWNLOAD OR IMPLEMENT ANY SERVICE PACK OR WORKAROUND, OR ANY OF THE TIPS, TRICKS, EXAMPLES OR SUGGESTIONS OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENTS. TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS ARE SUBJECT TO CHANGE WITHOUT NOTICE TO YOU. AUTODESK PROVIDES TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AUTODESK OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF DATA, OR LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, THAT MAY OCCUR AS A RESULT OF IMPLEMENTING ANY SERVICE PACK OR WORKAROUND, OR ANY SUGGESTION OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENT, EVEN IF AUTODESK OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.