Error Message—Not enough memory to run the radiation modelIssueStart-up processing of a radiation analysis stops with one of the following errors: The view factor calculation failed due to insufficient memory Not enough memory to run the radiation model Memory allocation exceeded in view factor calculation Not enough memory to achieve adequate sampling rate SolutionWhen view factors are processed, Autodesk® Simulation CFD probes the computer to find the maximum memory that the OS can provide for this task.
Once the amount of memory is known, Autodesk® Simulation CFD automatically adjusts internal accuracy set points to compute the view factors.
After the view factors have been computed, Autodesk® Simulation CFD checks if the sum of all view factors for every face in the model sums to 1.0. This error is issued if the computer simply does not have enough RAM to compute the view factors. To resolve this issue, change the mesh distribution to be coarser. Pay particular attention to the mesh distribution on surfaces. Try to reduce the number of element faces on surfaces, without compromising the flow solution. If necessary, simplify the geometry so that a coarser mesh can be applied. If the model still will not run after reducing the surface mesh density, add more RAM to the computer. Note that 32 bit machines are limited to 2Gbyte (3 Gbyte with the "3 Gigabyte switch"), but x64 machines are not subject to such a limitation.
Support – Terms of UseAUTODESK DOES NOT GUARANTEE THAT YOU WILL BE ABLE TO SUCCESSFULLY DOWNLOAD OR IMPLEMENT ANY SERVICE PACK OR WORKAROUND, OR ANY OF THE TIPS, TRICKS, EXAMPLES OR SUGGESTIONS OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENTS. TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS ARE SUBJECT TO CHANGE WITHOUT NOTICE TO YOU. AUTODESK PROVIDES TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AUTODESK OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF DATA, OR LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, THAT MAY OCCUR AS A RESULT OF IMPLEMENTING ANY SERVICE PACK OR WORKAROUND, OR ANY SUGGESTION OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENT, EVEN IF AUTODESK OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. |