Error Message—Compact Thermal Model ErrorsIssueA Compact Thermal Model material is assigned to a part. Upon startup, one or more of the following errors is issued: (Error 1): Theta JB is less than or equal to 0 (Error 2): Theta JC is less than or equal to 0 (Error 3): The surface part conductivity between the board and the CTM is less than or equal to 0 Solution
All of these issues are material property settings. Modify them using the Material Editor. (Click Edit on the Material task). (Error 1) Theta JB is the conductivity between the junction and the board. The value must be greater than 0 to make physical sense. To resolve, assign a value greater than 0 for Theta JB.
(Error 2) Theta JC is the conductivity between the junction and the case. Its value must be greater than 0 to make physical sense. To resolve, assign a value greater than 0 for Theta JC, the resistance between the junction and the case (Error 3) A surface part is placed between the PCB and the Compact Thermal Model. The thermal conductivity assigned to this part must be greater or equal to zero. To resolve, adjust the thermal conductivity of the surface part to be greater than 0.
Support – Terms of UseAUTODESK DOES NOT GUARANTEE THAT YOU WILL BE ABLE TO SUCCESSFULLY DOWNLOAD OR IMPLEMENT ANY SERVICE PACK OR WORKAROUND, OR ANY OF THE TIPS, TRICKS, EXAMPLES OR SUGGESTIONS OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENTS. TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS ARE SUBJECT TO CHANGE WITHOUT NOTICE TO YOU. AUTODESK PROVIDES TECHNICAL DOCUMENTS, SERVICE PACKS AND WORKAROUNDS "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AUTODESK OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF DATA, OR LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, THAT MAY OCCUR AS A RESULT OF IMPLEMENTING ANY SERVICE PACK OR WORKAROUND, OR ANY SUGGESTION OUTLINED IN ANY AUTODESK PRODUCT SUPPORT TECHNICAL DOCUMENT, EVEN IF AUTODESK OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. |