Autodesk Simulation CFD Services & Support

Countdown in Status Bar—is the Simulation Hung?

Issue

A running analysis appears to stall, and a countdown appears in the lower left corner of the Status bar:

 "Getting 1/69"

Solution

The first number increments from 1 up to the higher number.

This occurs at the conclusion of an analysis that was run using Remote Computing. The numbers indicate that information is transmitted from the Solver machine back to the local (User) machine. Large models may appear to stall because of the large volume of data that is received from the Solver machine. As long as the counter is incrementing, the analysis is not actually hung.